Home / GP LAB / Mass spectrometry / Chirality & stereochemistry

GP LAB · EXPERIMENTS

Chirality & stereochemistry

Marfey derivatization, deuterated hydrochloric acid hydrolysis and mass spectrometry support D/L amino-acid identification and quantification, with assessment and appropriate correction of hydrolysis-induced racemization. Intact-peptide epimers, site-specific configuration and Asp/isoAsp isomers can be investigated for a defined brief.

01

Qualitative and Quantitative Analysis of Free D/L Amino Acids

D- and L-amino acids already present in free form are identified and quantified in peptide ingredient solutions or formulations without total hydrolysis. Depending on the analyte and matrix, suitable chiral derivatization or chiral stationary-phase separation is coupled with LC–MS. Reports can provide concentrations of individual free enantiomers and D/L ratios for checking free components, ingredient quality or changes in chiral amino acids in a formulation, with comparison against peptide-bound results obtained after hydrolysis.

Supporting methods

  • Direct enantiomer analysis by chiral stationary-phase LC–MS

02

Chiral Amino Acid Composition Analysis of Peptide Hydrolysates

Constituent amino acids released by peptide hydrolysis are assigned and measured as D- and L-forms using chiral derivatization and LC–MS. Applications include synthetic peptides designed to contain D-residues, ingredient quality control and stereochemical comparisons. FDAA, FDLA, S-NIFE or advanced Marfey derivatization routes can be assessed according to the residues and separation requirements. Results can include constituent-amino-acid D/L composition, comparator results and the hydrolysis conditions used.

Supporting methods

  • FDAA precolumn chiral derivatization and reversed-phase LC–MS (Marfey method)
  • FDLA precolumn chiral derivatization and LC–MS
  • S-NIFE chiral derivatization and LC–MS/MS quantification
  • High-sensitivity advanced Marfey analysis of amino-acid configuration

03

Advanced Marfey’s Analysis Using L-/D-FDLA

Amino acids from the sample and suitable references are independently derivatized with the two configurations of FDLA. LC–MS retention behaviour and target signals are then used to investigate absolute configuration under suitable conditions. The approach is applicable to residues or special samples that are difficult to assign using a conventional single-reagent comparison. Deliverables can include paired derivatization chromatograms, reference comparisons and assignment reasoning, with further verification identified for residues requiring standards or other evidence.

04

Comparative HCl/DCl Hydrolysis for D/L Ratio Assessment and Correction

The same peptide undergoes parallel hydrolysis with hydrochloric acid and deuterated hydrochloric acid, followed by chiral derivatization and MS comparison of D/L results. Observable deuterium incorporation during hydrolysis is used to trace configuration changes. The study addresses the distinction between trace isomers in the original sample and hydrolysis-induced racemization. Deliverables can include chromatograms from both conditions, treatment of isotope interference and correction calculations, with estimates of the original residue ratios supported by full-process controls.

Supporting methods

  • Deuterated hydrochloric acid hydrolysis and tracing of hydrolysis-induced racemization

05

Quantification of Trace Opposite-Configuration Amino Acids in Peptides

Selective quantification methods are developed for trace amino acids of the opposite configuration in a peptide designed around a specified configuration. One example is measurement of trace L-phenylalanine in a peptide specified to contain D-phenylalanine. Chiral separation, reaction controls and, where necessary, evaluation of hydrolysis-induced racemization can support the work. Deliverables can include applicable quantification limits and residue molar proportions to compare batches, assess process effects and check quality attributes.

06

Separation, Identification and Quantification of Intact Peptide Epimers

Chromatographic separation is screened for intact peptides differing at individual stereocentres while retaining the peptide chain. MS and/or synthetic isomer comparators are used for peak assignment. Applications include quality control of a parent peptide and specified epimers, synthesis-process screening and investigation of abnormal peaks. Deliverables can include separation profiles, assignment evidence and, where the method is suitable, content or proportion data to compare isomers at the intact-molecule level.

07

Enantiomeric Purity Testing of Intact Peptides

Chiral-recognition and quantification strategies are assessed for intact peptide molecules and their full mirror-image enantiomers. Suitable chiral chromatography or another verifiable recognition approach is selected according to sequence, modification and sample properties, using enantiomer references to establish peak assignments. Where sufficient separation is achieved, enantiomer proportions, chromatographic evidence and quantitative ranges can be reported to support development of an enantiomeric-purity specification for the particular peptide.

08

Site-Specific Localization of D/L Residues in Peptides

Suitable partial hydrolysis, fragment separation or enzymatic digestion is used to retain local sequence relationships when locating D- or L-residues in a peptide chain. Chiral analysis and comparator studies are then applied. The approach is relevant when the same residue occurs more than once and total hydrolysis gives only an overall ratio. Deliverables can identify fragment coverage, evidence supporting particular sites and potentially coexisting structures, with directions for preparing additional site-specific comparators.

09

Stereoisomer Analysis of Isoleucine and Threonine Including Allo Forms

Separation and assignment methods are developed for the stereoisomers of isoleucine and threonine, including allo forms associated with their additional stereocentres. Applications include ingredients, modified peptides and synthesis-process comparators with specified stereochemistry. Depending on analyte and standard coverage, deliverables can include separation profiles, reference retention data and quantitative results, helping identify isomers that may be missed when only one D/L reference pair is used.

10

Absolute Configuration Analysis of Nonproteinogenic and Modified Amino Acids

For nonproteinogenic or modified amino acids, release conditions, chiral derivatization reactions and MS responses are assessed for the particular structure to establish an assignment workflow. The study is applicable to research peptides with nonstandard residues, ingredients with special stereochemistry and candidate-structure comparisons. Deliverables can include sample and available-standard LC–MS evidence, configuration assessments and key limitations, supporting custom synthesis and subsequent structural quality control.

11

Characterization and Site Analysis of Asp/isoAsp Peptide Isomers

Separation conditions, comparator standards and suitable fragmentation or ion-mobility information are combined to investigate Asp/isoAsp linkage differences and their possible positions in peptides. Applications include investigation of deamidation- or isomerization-related impurities, stability studies and comparison of candidate isomeric peaks. Results can identify principal isomeric peaks, evidence for linkage form or position, and further enzymatic, separation or synthetic-reference studies needed for verification.

12

Multipass Cyclic Ion Mobility Separation of Peptide Isomers

Multipass separation conditions are screened using cyclic ion mobility for peptide isomers with similar masses. The relationship between pass number, separation and signal loss is assessed. For epimers with structural comparators, mobility distributions and fragment fingerprints can support assignments. Deliverables can include mobility plots for samples and comparators, separation performance and the applicable scope, supporting complex-isomer identification and development of subsequent quantitative conditions.

Supporting methods

  • Comparison of mobility and fragment fingerprints of peptide epimers